Solution
INSPECTION PROCESS I
-
ISSUE-1: HARDEN, FLANK WEAR
-
ISSUE-2: WORKING BELT NOISE
-
ISSUE-3: BELT BREAK AFTER SHORT TIME WORKING
-
ISSUE-4: BELT WORN INPROPORTIONATE
-
ISSUE-5: BELT RIB HAS CRACK OR SPALLING
-
ISSUE-6: POLLUTION
- TENSION IS INCORRECT
- BELT REINFORCEMENT WAS DAMAGED BECAUSE OF WRONG INSTALLATION
REMEDIAL SOLUTION-1:CHANGE BELT AND ADJUST CORRECT TENSION CHANGE BELT AND INSTALL BELT CORRECTLY
- LOW TENSION
- EXCEED OF LIFETIME
REMEDIAL SOLUTION-2:TENSION BELT OR CHANGE BELT CHANGE BELT
- BELT REINFORCED WIRE DAMAGED BECAUSE OF WRONG
- HIGH TENSION
REMEDIAL SOLUTION-3:CHANGE BELT AND INSTALL BELT CORRECTLY CHANGE BELT AND ADJUST CORRECT TENSION
- PULLEYS ARE NOT PARALLEL
- BELT HIGHLY VIBRATILITY
REMEDIAL SOLUTION-4:CHECK TRANSIMISSION SYSTEM ADJUST PLLEY AND CHANGE PULLEY CHECK TENSION, TENSL OR CHANGE PULLEY IF NECESSARY
- TENSION IS HIGH OR LOW
- EXCEEO OF LIFETIME
- STUFF
REMEDIAL SOLUTION-5: CHANGE BELT AND ADJUST CORRECT TENSION CHANGE BELT
- ENGIN OR PARTS LEAK,OIL ORANTI-FREEZING LIQUID
REMEDIAL SOLUTION-6:STOP LEAK CHANGE BELT
INSPECTION PROCESS II
-
ISSUE-1: NOISE
-
ISSUE-2: BELT TEETH AND FABERIC BREAKOFF
-
ISSUE-3: SYSTEM PART APPEARS WORKING FAULT
-
ISSUE-4: GEAR WORN/ BASE CRACK AND TEETH BREAK OFF
-
ISSUE-5: BELT SIDE WEAR
-
ISSUE-6: BELT TEETH DAMAGED
-
ISSUE-7: TIMING BELT TEETH GROOV WORN
-
ISSUE-8: TIMING BELT BREAK
-
ISSUE-9: BELT TEETH DAMAGED/BELT TOP SIDE WEAR
- HIGH TENSION: BELT MAKES BIG NOISE WHEN WORKING
- LOWER TENSION: WORKING BELTHITPROTECTIVE DEVICE
REMEDIAL SOLUTION-1:ADJUST CORRECT TENSION
- ENGINOR ENGIN PARTSLEAK OILORANTIFREEZE FLUID
REMEDIAL SOLUTION-2:- STOP LEAKING AND CHANGE BELT
- BEARING BREAK OFF
- WORKING SURF ACE DAMAGED
REMEDIAL SOLUTION-3:CHANGE GUIDE PULLEY, TENSION ROLLER OR GUIDE ROLLER
- TENSIONIS ARE HIGH OR LOW
- STUFF ENTERS INSIDE BETWEEN BELT AND GEAR
- TIMINGBELT OR IDLER PULLEY LOCKED
REMEDIAL SOLUTION-4:- CLEAR OUT THE STUFF - CHECKING IF THE TRANSMISSION PROTECTIVE DEVICE INSTALLED CORRECTLY OR NOT
- PULLEY AND IDLER PULLEY ARE NOT PARALLEL AND BELT IS WORKING ON THE PULLEY SIDE ONLY
- PULLEY AND IDLER PULLEY ARE NOT INSTALLED CORRECTLY AND BELT IS WORKING ONLY ON THE PULLEY SIDE
- FLANGED SHAFT PULLEY APPEARS FAULT
- PULLEY ORIDLERPULLEY BREAKOFF
REMEDIAL SOLUTION-5: - SOLUTION FOR 1 AND 2: CHECK TRANSMISSION AND INSTALL PULLEY POSITION CORRECTLY - SOLUTION FOR 3 AND 4: CHANGE PARTS
- SOME STUFF BETWEEN BELT AND PULLEY
- TIMING PULLET TEETH DAMAGED CAUSED BY STUFF OR INSTALLATION TOOLS
- TIMING BELT DAMAGED BEFORE OR AFTER INSTALLATION
REMEDIAL SOLUTION-6:STOP - TAKE OFF STUFF, CHANGE BELT AND CHECK IF THE TRANSMISSION PROTECTIVE DEVICE INSTALLED CORRECTLY OR NOT - CHANGE DAMAGED TIMING BELT PULLEY AND CHANGE BELT TO BE INSTALLED CORRECTLY - CHANGE BELT AND INSTALL IT CORRECTLY
- TENSION SET TOO HIGH
- TIMING PULLEY WORN
REMEDIAL SOLUTION-7:- CHANGE BELT AND SET CORRECT TENSION / - CHAGNE TIMING PULLEY AND BELT
- SOME STUFF IN TRANSMISSION DEVICE
- POLLUTION EFFECTION
- HIGH TENSION
- TIMING BELT TURNUP BEFORE ORAFTER INSTALWION
REMEDIAL SOLUTION-8:
- - CLEAN OUT OF THE STUFF AND CHANGE BELT
- - CAHNGE BELT, CHECK TRANSMISSION PROTECTIVE DEVICE INSTALLED CORRECTLY OR NOT
- - CHANGE BELT. SET CORRECT TENSION
- - CHANGE BELT AND INSTALL BELT CORRECT
- WORKING CONDITION WITH HIGH/LOWTEMPERATURE
- POLLUTION EFFECTION
- DAMAGE IDLER PULLEY OR BREAKOFF
- AGING
REMEDIAL SOLUTION-9:
- - CHECKING REASON AND CORRECT IT AND CHANGE BELT
- - CHANGE BELT, CHECK TRANSMISSION PROTECTIVE DEVICE INSTALLED CORRECTLY OR NOT
- -CHANGE BELTAND IDLER PULLEY
- -CHANGE BELT
INSPECTION PROCESS III
-
ISSUE-1: BELT SIDE WORN
-
ISSUE-2: BELT SECTONWORN DISPROPORIONATELY
-
ISSUE-3: BELT WORKING NOISE
-
ISSUE-4: BELT BASE CRACK AND SPALLATION
-
ISSUE-5: BELT BREAK AFTER SHORT TIME WORKING
-
ISSUE-6: BELT POLLUTION
-
ISSUE-7: BELT HARDEN, BELT SIDE WORN
-
ISSUE-8: HIGH WEAR ON THE SIDE
- TENSION IS MISATKE
- BELT REINFORCED WIRE DAMAGEDBECAUSE OF WRONG INSTALLATION
REMEDIAL SOLUTION-1:
- - CHANGE BELT, SET CORRECT TENSION
- -CHANGE BELT AND INSTALLIT CORRECTLY
- BELTPULLEY INSTALLED BY MISTAKES
- BELT HIGHLY VIBRATILITY
REMEDIAL SOLUTION-2:
- - CHECK TRANSMISSION SYSTEM
- - CORRECTLY INSTALLED OF PUTTEY POSITION AND CHANGE IT IF NECESSARY
- LOW TENSION
- EXCEED BELT LIFETIME
REMEDIAL SOLUTION-3: - ADJUST TENSION OR CHANGE BELT
- BELT TENSION IS TOO HIGH OR LOW
- EXCEED IF BELT LIFETIME
- STUFF COME INSIDE BETWEEN BELT AND PULLEY
REMEDIAL SOLUTION-4:
- - CHANGE BELT, SENT CORRECT TENSION
- - 2&3: CHANGE BELT
- BELT REINFORCED WIRE DAMAGED
- BECAUSE OF WRONG INSTALLATION
- HIGH TENSION
REMEDIAL SOLUTION-5:
- - CHANGE BELT AND INSTALL IT CORRECTLY
- - CHANGE BELT, SET CORRECT TENSION
- ENGIN OR ENGIN PARTS LEAK,OILORANTIFREEZE FLUID
REMEDIAL SOLUTION-6:- STOP LEAK AND CHANGE BELT
- PULLEY NOT PARALLEL
- BELT REINFORCED WIRE DAMAGED BEC. AUSE OF WRONG INSTALLATION
- DEVICE JNSTALLED MISTAKES
REMEDIAL SOLUTION-7:
- - CHECK TRANSMISSION SYSTEM ADJUSTIN. CORRECT INSTALLEDOF PULLEYPOSITION. AND CORRECTLY INSTALLNEW BELT DEVICE
- -CHANGE BELT AND CORRECTLY INSTALL
- - ONLY CHANGE ALL SET OF BELT DEVICE
- BELT CREEP
- PULLEY NOT PARALL EL3.PULLEY GROOV WORN
REMEDIAL SOLUTION-9:
- - CHANGE BELT AND SET TENSION CORRECTLY
- - CHECK TRANSMISSION SYSTEM, ADJUST IN. CORRECTLY INSTALLED OF PULLEY POSITION, AND CHANGE IT IF NECESSARY
- - CORRECTLY INSTALL OR CHANGE PULLEY AND
SAFETY GUIDELINES
How To STORAGE
- TIMING BELT SHOULD BE PUT IN THE DRY AND COOL PLACE FOR LONG TIME STORAGE AND TEMPERATURE SHOULD BETWEEN 15°C-25°C TO KEEP GOOD QUALITY AFTER FEW YEARS.
- INCORRECT STORAGE WILL CHANGE RUBBER PHYSICAL FEATURES,WHICH WAS CAUSED BY OXYGEN, OZONE,ULTIMATE TEMPERATURE, ILLUMINATION, HUMIDITY AND SOLVEN CONDITIONS.